Home ProductsGenset Power Plant

Customized HFO and diesel oil Genset Power Plant Water and air Cooling Generator 0.4KV-11KV 500-1000RPM

China KANGWEI ENVIRONMENT ENERGY GROUP certification
China KANGWEI ENVIRONMENT ENERGY GROUP certification
We enjoy marine support from the WUXI KANGWEI since 2001, they have the appreciated experience in HFO fired diesel engine , HFO treatment system

—— Mr.Hua Hadi ,Haiphong shipyard

whenever the marine problem is related to the HFO treatment ,purification analysis of HFO power plant ,we rely on the support provided by the KANGWEI

—— Mr.Ali Hadi , Baghdad,Iraq

We trust the supported of them,They look at the heavy fuel oil system problem of power plant from different angles using different technologies.

—— Mr.MAHMOUD HADY,Saudi Arabia

I'm Online Chat Now

Customized HFO and diesel oil Genset Power Plant Water and air Cooling Generator 0.4KV-11KV 500-1000RPM

Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM
Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM

Large Image :  Customized HFO and diesel oil Genset Power Plant Water and air Cooling Generator 0.4KV-11KV 500-1000RPM

Product Details:
Place of Origin: WUXI , CHINA
Brand Name: KWEE
Certification: ISO IEC ASTM
Model Number: According to the design and technical demand
Fuel: gas, diesel oil ,heavy fuel oil
Payment & Shipping Terms:
Minimum Order Quantity: 1SET
Price: negotiated
Packaging Details: CONTAINER ,WOODEN CASE
Delivery Time: Negotiate
Payment Terms: T/T, L/C
Supply Ability: depend on the designing capacity
Detailed Product Description
High Light:

Genset Diesel Generator Set

,

Diesel Engine Power Plants

Custom Genset Power Plant Water Cooled Diesel Generator 11KV 750Rpm

 

 

G300 Statinary Generating Sets Main Specification
Model 1000GF1 1250GF3 1350GF4 1400GF4
Rated power, KW 1000 1250 1350 1400
Overload , KW 1100 1375 1485 1540
Rated voltage, V 400/415/440/3300/6300/10500/13800
Rated current , A                
Frequency , Hz 50 60 50 60 50 60 50 60
Power factor 0.8 Lagging
Phase 3
Diesel engine G6300ZD6 G6300ZD8 G8300ZD6 G6300ZD10 G8300ZD10 G8300ZD8 G8300ZD10 G8300ZD8
Rated power, KW 1103 1470 1471 1471 1765 2000 1765 2000
Rated rev, rpm 500 600 500 600 500 600 500 600
Alternator 3 phase alternator
voltage fluctuation rate% <0.5 <0.5
Frequency fluctuation rate, % <0.5 <0.5
Stable voltage regulating rate, % ±1.0 ±1.0
Transient voltage regulating rate, % +20, -15 +20, -15
Stable Frequency fluctuation rate, % <3 <0.5
Transient frequency regulating rate, % +12, -10
Stablizing time, voltage , S <4
Stablizing time, frequency , S <3
voltage regulating method automatic and munual
Frequency regulating method manual
starting method compressed air
Lubricating method pressue lubricating 
Cooking method water cooling
coupling flexible
Overdimension, mm 3880*2150*3180 8470*2360*3060
Weight, Kg 30000 35000 38000
G300 Statinary Generating Sets Main Specification
1500GF6 1600GF5 1800GF7 2000GF8
1500 1600 1800 2000
1650 1760 1980 2200
400/415/440/3300/6300/10500/13800
               
50 60 50 60 50 60 50 60
0.8 Lagging
3
G8300ZD10 G8300ZD8 G8300ZD10 G8300ZD8 G8300ZD8 G8300ZD8 G8300ZD12 G8300ZD8
1765 2000 1765 2000 2000 2000 2206 2000
500 600 500 600 600 600 600 600
3 phase alternator
<0.5
<0.5
±1.0
20, -15
<0.5
+20, -15
<5
<4
automatic and munual
manual
compressed air
pressue lubricating 
water cooling
flexible
8470*2360*3060
38000 42560

 

 

Remark

 

1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure 100kpa

charge air coolant temperature 25℃

relative humidity 30%

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position

 

 

GN8320 Stationary Generating Sets Main Specification

Model

2400GF

2500GF

Rated power, KW

2400

2500

Overload , KW

2640

2750

Rated voltage, V

400

415

3300

6300

10500

400

415

3300

6300

10500

Rated current , A

4330

4174

525

275

165

4511

4348

547

172

286

Frequency , Hz

50

50

Power factor

0.8 Lagging

0.8 Lagging

Phase

3

3

Diesel engine

GN832000ZD

GN8320ZD

Rated power, KW

2648

2795

Rated rev, rpm

750

750

Alternator

3 phase alternator

voltage fluctuation rate%

±1.0

Frequency fluctuation rate, %

+12, -10

Stable voltage regulating rate, %

3

Transient voltage regulating rate, %

+12, -10

Stable Frequency fluctuation rate, %

4

 

Transient frequency regulating rate, %

5

Stabilizing time, voltage , S

+1

Stabilizing time, frequency , S

+12, -10

voltage regulating method

automatic and manual

Frequency regulating method

manual

starting method

compressed air

Lubricating method

pressure lubricating

Cooking method

water cooling

coupling

flexible

Overdimension, mm

8950*2570*6050

Weight, Kg

45000

 

 

Remark

1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure

charge air coolant temperature

relative humidity

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position

 

Customized HFO and diesel oil Genset Power Plant Water and air  Cooling Generator 0.4KV-11KV  500-1000RPM 0

 

 

Contact Details
KANGWEI ENVIRONMENT ENERGY GROUP

Contact Person: Mr. David Liu

Tel: +86-13812510495

Fax: 86-510-85115375

Send your inquiry directly to us (0 / 3000)